Place of Origin:

East, 1st floor, Building 2, Changan Industrial Park, 288 Wei 17 Road, Yueqing Economic Development Zone

Brand Name:

ZJYUXING

Model Number:

KYN61-40.5

Certification:

图片2.png

Environmental conditions for use

1. Environmental temperature: Upper limit+40C, and the average value measured within 24 hours does not exceed 35C, lower limit -10C.

2. Altitude: The altitude shall not exceed 1000m.

3. Relative humidity: The daily average value shall not exceed 95%, and the monthly average value shall not exceed 90%.

4. Seismic intensity: not exceeding 8 degrees.

5. Surrounding environment: Places without fire, explosion hazard, serious pollution, chemical corrosion, and severe vibration.

Main features

1. The cabinet structure adopts an assembled type, and the circuit breaker adopts a handcart floor structure;

2. Equipped with a brand new composite insulated vacuum circuit breaker, with the characteristics of good interchangeability and easy replacement;

3. The handcart frame is equipped with a screw nut pushing mechanism, which can easily move the handcart and prevent accidental operation from damaging the pushing structure

All operations can be carried out with the cabinet door closed;

5. The interlocking between the main switch, handcart, and switch cabinet door adopts a mandatory mechanical locking method, meeting the "five prevention" function;

6. The cable room has ample space and can connect multiple cables;

7. Quick grounding switch is used for grounding and circuit short circuit;

8. The shell protection level is IP4X, and when the handcart compartment door is open, the protection level is IP2X:

9. The product complies with GB3906-1991, DL404-1997, and adopts international IEC-298 standards as reference.

Vacuum switch cabinet main technical parameters

NAME

UNIT

DATA

Rated voltage

kV

40.5

Rated lightning shock resistance voltage

kV

185

Rated power frequency withstand voltage

kV

95/1 min

Rated frequency

Hz

50

Rated current

A

630 1250 1600 2000

Rated short-time withstand current

KA

20 25 31.5

Rated peak tolerable current

kA

50 63 80

Rated short-circuit breaking current

KV

20 25 31.5

Rated short circuit duration

s

4

Protection class

 

IP4X

 

 

 

 Vacuum circuit breaker main technical parameters

NAME

UNIT

DATA

ZH85A-40.5/VD4

SF1/SF2

Rated voltage

KV

40.5

Rated lightning shock resistance voltage

KV

185

Rated power frequency withstand voltage

KV

95/1 min

Rated frequency

HZ

50

Rated current

A

1250 1600 2000

630 1250 2500

Rated short-circuit breaking current

KV

20 25 31.5

25 31.5

Rated peak short-circuit closing current

KA

50 63 80

63 80

Rated peak dynamic stable current

KA

50 63 80

63 80

4s Effective thermal stable current

KA

20 25 31.5

25 31.5(3s)

Opening time

ms

36~60

≤45

Closing time

ms

40~90

≤75

Rated operating sequence

 

open-0.3s-closed open-180s-closed open